• Call : +86 13506151153
  • allen@zozen.com

What is the reason that the temperature difference between the inlet oil and the outlet oil in therm

What is the reason that the temperature difference between the inlet oil and the outlet oil in therm

  • 12 Jul 2018
  • by ZOZEN Boiler
  • 366 comments

(Question details) Specific performance:

The temperature difference between the inlet oil and the outlet oil temperature of the boiler exceeds the given value.

Answer:Cause of failure:

(1) The oil supply of the heat oil circulating pump is insufficient.

(2) The boiler operates overload.

(3) Thermal oil metamorphism.

(4) The boiler does not match the heating equipment.

(5) Bad insulation effect.

(6) There is gas or steam in the thermal oil.

Troubleshooting:

(1) Remove the faults of oil pump and pipeline.

(2) Operate at normal load.

(3) Change new oil.

(4) Choose proper boiler.

(5) Check the insulation layer and repair the loopholes.

(6) Remove air or steam.

ZOZEN pays much attention to boiler furnace insulation also, the inside is made of high quality insulation material, external use of stainless steel plate, which can maximumly reduce heat loss and improve the operating environment.

 

Leave a comment

Make sure you enter all the required information, indicated by an asterisk (*). HTML code is not allowed.

About Company

We supply to over 100 countries and regions and have set up offices around the world to ensure prompt delivery of products and services.

Provide opportunities for employees.

Customer service

If you run into any problems with the boiler, please contact us directly by email or fill out the online service request. We will do our best to resolve any problems you might have within 24 hours.

Corporate Office

  • No. 76, Xin Da Road, Zhou tie Town, Yixing, Wuxi, China
  • +86 13506151153
  • allen@zozen.com
  • Fax : 0086-510-68991001

Search